SARS-CoV-2 antibodies in the Southern Region of New Zealand, 2020
Abstract
Background
During New Zealand’s first outbreak in early 2020 the Southern Region had the highest per capita SARS-CoV-2 infection rate. PCR testing was initially limited by a narrow case definition and limited laboratory capacity, so cases may have been missed.
Objectives
To evaluate the Abbott ® SARS-CoV-2 IgG nucleocapsid assay, alongside spike-based assays, and to determine the frequency of antibodies among PCR-confirmed and probable cases, contacts, and higher risk individuals in the Southern Region of NZ.
Study design
Pre-pandemic sera (n=300) were used to establish assay specificity and sera from PCR-confirmed SARS-CoV-2 patients (n=78) to establish sensitivity. For prevalence analysis, all samples (n=1214) were tested on the Abbott assay, and all PCR-confirmed cases (n=78), probable cases (n=9), and higher risk individuals with grey-zone (n=14) or positive results (n=11) were tested on four additional SARS-CoV-2 serological assays.
Results
The median time from infection onset to serum collection for PCR-confirmed cases was 14 weeks (range 11-17 weeks). The Abbott assay demonstrated a specificity of 99.7% (95% CI, 98.2%-99.99%) and a sensitivity of 76.9% (95% CI, 66.0%-85.7%). Spike-based assays demonstrated superior sensitivity ranging 89.7-94.9%. Nine previously undiagnosed sero-positive individuals were identified, and all had epidemiological risk factors.
Conclusions
Spike-based assays demonstrated higher sensitivity than the Abbott IgG assay, likely due to temporal differences in antibody persistence. No unexpected SARS-CoV-2 infections were found in the Southern region of NZ, supporting the elimination status of the country at the time this study was conducted.
Related articles