A Simplified Point-of-Care Lung Ultrasound Protocol to Detect Coronavirus Disease 2019 in Inpatients: A Prospective Observational Study
Abstract
Objectives
To assess the diagnostic performance of lung point-of-care ultrasound (POCUS) compared to either a positive nucleic acid test (NAT) or a COVID-19-typical pattern on computed tomography (CT) and to evaluate opportunities to simplify a POCUS algorithm.
Methods
Hospital-admitted adult inpatients with (1) either confirmed or suspected COVID-19 and (2) a completed or ordered CT within the preceding 24 hours were recruited. Twelve lung zones were scanned with a handheld POCUS machine. POCUS, CT, and X-ray (CXR) images were reviewed independently by blinded experts. A simplified POCUS algorithm was developed via machine learning.
Results
Of 79 enrolled subjects, 26.6% had a positive NAT and 31.6% had a CT typical for COVID-19. The receiver operator curve (ROC) for a 12-zone POCUS protocol had an area under the curve (AUC) of 0.787 for positive NAT and 0.820 for typical CT. A simplified four-zone protocol had an AUC of 0.862 for typical CT and 0.862 for positive NAT. CT had an AUC of 0.815 for positive NAT; CXR had AUCs of 0.793 for positive NAT and 0.733 for typical CT. Performance of the four-zone protocol was superior to CXR for positive NAT (p=0.0471). Using a two-point cutoff system, the four-zone POCUS protocol had a sensitivity of 0.920 and 0.904 compared to CT and NAT, respectively, at the lower cutoff; it had a specificity of 0.926 and 0.948 at the higher cutoff, respectively.
Conclusion
POCUS outperformed CXR to predict positive NAT. POCUS could potentially replace other chest imaging for persons under investigation for COVID-19.
Related articles
Related articles are currently not available for this article.