Detection of neutralizing antibodies against SARS-CoV-2 by using a commercial surrogate virus neutralization ELISA: can it substitute the classical neutralization test?

This article has 1 evaluations Published on
Read the full article Related papers
This article on Sciety

Abstract

Background

High-throughput detection of neutralizing antibodies against SARS-CoV-2 presents a valuable tool for vaccine trials or investigations of population immunity. We evaluate the performance of the first commercial surrogate virus neutralization test (sVNT, GenScript Biotech) against SARS-CoV-2 plaque reduction neutralization test (PRNT) in convalescent and vaccinated individuals. We compare it to five other ELISAs, two of which are designed to detect neutralizing antibodies.

Results

In 491 pre-vaccination serum samples, sVNT missed 23.6% of PRNT-positive samples when using the manufacturer-recommended cutoff of 30% binding inhibition. Introducing a equivocal area between 15 and 35% maximized sensitivity and specificity against PRNT to 72.8–93.1 % and 73.5– 97.6%, respectively. The overall diagnostic performance of the other ELISAs for neutralizing antibodies was below that of sVNT. Vaccinated individuals exhibited higher antibody titers by PRNT (median 119.8, IQR 56.7–160) and binding inhibition by sVNT (median 95.7, IQR 88.1–96.8) than convalescent patients (median 49.1, IQR 20–62; median 52.9, IQR 31.2–76.2).

Conclusion

GenScript sVNT is suitable to screen for SARS-CoV-2-neutralizing antibodies; however, to obtain accurate results, confirmatory testing by PRNT in a equivocal area is required. This equivocal area may require adaptation for use in vaccinated individuals, due to higher antibody titers.

Related articles

Related articles are currently not available for this article.