Optimising the balance of acute and intermediate care capacity for the complex discharge pathway: computer modelling study during COVID-19 recovery in England
Abstract
Objectives
While there has been significant research on the pressures facing acute hospitals during the COVID-19 pandemic, there has been less interest in downstream community services which have also been challenged in meeting demand. This study aimed to estimate the theoretical cost-optimal capacity requirement for ‘step down’ intermediate care services within a major healthcare system in England, at a time when considerable uncertainty remained regarding vaccination uptake and the easing of societal restrictions.
Methods
Demand for intermediate care was projected using an epidemiological model (for COVID-19 demand) and regressing upon public mobility (for non-COVID-19 demand). These were inputted to a computer simulation model of patient flow from acute discharge readiness to bedded and home-based Discharge to Assess (D2A) intermediate care services. Cost-optimal capacity was defined as that which yielded the lowest total cost of intermediate care provision and corresponding acute discharge delays.
Results
Increased intermediate care capacity is likely to bring about lower system-level costs, with the additional D2A investment more than offset by substantial reductions in costly acute discharge delays (leading also to improved patient outcome and experience). Results suggest that completely eliminating acute ‘bed blocking’ is unlikely economical (requiring large amounts of downstream capacity), and that health systems should instead target an appropriate tolerance based upon the specific characteristics of the pathway.
Conclusions
Computer modelling can be a valuable asset for determining optimal capacity allocation along the complex care pathway. With results supporting a Business Case for increased downstream capacity, this study demonstrates how modelling can be applied in practice and provides a blueprint for use alongside the freely-available model code.