Tongue swab testing on two automated tuberculosis diagnostic platforms, Cepheid Xpert® MTB/RIF Ultra and Molbio Truenat® MTB Ultima

This article has 5 evaluations Published on
Read the full article Related papers
This article on Sciety

Abstract

Tongue dorsum swabbing is a potential alternative to sputum collection for tuberculosis (TB) testing. Previous studies showed that Cepheid Xpert® MTB/RIF Ultra (Xpert Ultra) can detectMycobacterium tuberculosis(MTB) DNA in tongue swabs stored in buffer, with 72% sensitivity and 100% specificity relative to a sputum microbiological reference standard (sputum MRS). The present study evaluated a more convenient sample collection protocol (dry swab storage), combined with streamlined sample processing protocols, for side-by-side analysis using two commercial TB diagnostic tests: Xpert Ultra and Molbio Truenat® MTB Ultima (MTB Ultima). Copan FLOQSwabs were self-collected, or collected by study workers, from 321 participants in Western Cape, South Africa. All participants had symptoms suggestive of TB, and 245 of them had sputum MRS-confirmed TB (by sputum culture and/or Xpert Ultra). One tongue swab per participant was tested on Xpert Ultra and another tongue swab was tested with MTB Ultima. Xpert Ultra was 75.4% sensitive and 100% specific, and MTB Ultima was 71.6% sensitive and 96.9% specific, relative to sputum MRS. When sample lysates that were false-negative by MTB Ultima were frozen, thawed, and re-tested, MTB Ultima sensitivity rose to 79.1%. Both tests were more sensitive with swabs from participants with higher sputum Xpert semi-quantitative results. The protocol for Xpert Ultra enabled fast and easy testing of dry-stored swabs with no loss of accuracy relative to previous methods. MTB Ultima testing of dry-stored swabs exhibited comparable performance to Xpert Ultra. These results further support tongue swabs as easy-to-collect samples for high-throughput TB testing.

Related articles

Related articles are currently not available for this article.